The tape format consists of a 256 byte file header, with files separated by a single file mark. Data blocks are 32768 bytes. There is also a file mark output every 10000 data blocks. This is taken care of in the software.
The new disc format has 32768 byte data buffers with an additional 8 byte header which differentiates between header and data blocks.
The current handler supports a configuration file that defines the mapping between Oak Ridge parameter number and MTsort group/item numbers.
There is a default configuration file which may be modified by entering the "Config" option within the Input Handler window.
If we consider the following list of parameter numbers ...
======================================================================= ADC # Signal Signal ADC # ----------------------------------------------------------------------- 101 Clover 1A energy sideLeft 251 102 1B sideMiddle 252 103 1C sideRight 253 104 1D time 201 --------------------------------------------------- Clovers 105 Clover 2A energy sideLeft 254 106 2B sideMiddle 255 107 2C sideRight 256 108 2D time 205 --------------------------------------------------- 109 Clover 3A energy sideLeft 257 110 3B sideMiddle 258 111 3C sideRight 259 112 3D time 209 --------------------------------------------------- 113 Clover 4A energy sideLeft 260 114 4B sideMiddle 261 115 4C sideRight 262 116 4D time 213 --------------------------------------------------- 117 Clover 5A energy sideLeft 263 118 5B sideMiddle 264 119 5C sideRight 265 120 5D time 217 --------------------------------------------------- 121 Clover 6A energy 122 6B not segmented 123 6C 124 6D time 221 ----------------------------------------------------------------------- 125 CSS1 energy time 225 126 CSS2 energy time 226 127 CSS3 energy time 227 128 CSS4 energy time 228 129 CSS5 energy time 229 small Ge's 130 CSS6 energy time 230 131 CSS7 energy time 231 132 CSS8 energy time 232 133 CSS9 energy time 233 134 CSS10 energy time 234 ----------------------------------------------------------------------- 901 Anode left 902 Anode right 903 Top Position 904 Bottom Sensitive 905 Left left Avalanche 906 Left right Counter 907 Right left 908 Right right "PSAC" 909 Energy left 910 Energy right ----------------------------------------------------------------------- 801 Anode 1 left 802 Anode 2 left 803 Sum anodes left 804 Anode 1 right 805 Anode 2 right Ionisation 806 Sum anodes right Chamber 798 Anode 3 left 799 Anode 3 right "IC" 807 IC left timing 808 IC right timing 809 IC-PSAC timing ----------------------------------------------------------------------- 191 Recoil - gamma TAC 192 Recoil - gamma - gamma TAC -----------------------------------------------------------------------
... then these may be mapped onto the following format statements ...
clover[1:6](energy1,energy2,energy3,energy4,time,sideL,sideM,sideR) ge[21:30](energy,time) psac[100](al,ar,top,bot,ll,lr,rl,rr,eleft,eright) ionc[200](a1l,a2l,suml,a1r,a2r,sumr,a3l,a3r,ltime,rtime,pictac) trigger[255](rgtac,rggtac)
... by the following config file ...
#clover[1:6](energy1,energy2,energy3,energy4,time,sideL,sideM,sideR) group 1 101 102 103 104 201 251 252 253 group 2 105 106 107 108 205 254 255 256 group 3 109 110 111 112 209 257 258 259 group 4 113 114 115 116 213 260 261 262 group 5 117 118 119 120 217 263 264 265 group 6 121 122 123 124 221 266 267 268 #Ge[21:30] (energy,time) group 21 125 225 group 22 126 226 group 23 127 227 group 24 128 228 group 25 129 229 group 26 130 230 group 27 131 231 group 28 132 232 group 29 133 233 group 30 134 234 #trigger[255] (getac,ggtac) group 255 191 192 #psac[100] (al,ar,top,bot,ll,lr,rl,rr,eleft,eright) group 100 901 902 903 904 905 906 907 908 909 910 #ionc[200] (a1l,a2l,suml,ar1,ar2,sumr,a3l,a3r,lpsact,rpsact,horiz) group 200 801 802 803 804 805 806 798 799 807 808 809
Maintained by Janet Sampson and John Cresswell (University of Liverpool)